Delfin DG50 EXP INERT Industrial Vacuum
ATEX Zone 22 Certified Industrial Vacuum with Inert Technology for Reactive Metal Dust
The Delfin DG50 EXP INERT is a specialist ATEX certified industrial vacuum cleaner designed for the safe collection and neutralisation of reactive and self-igniting metal dust in hazardous environments. Specifically engineered for ATEX Zone 22 applications, this advanced industrial vacuum combines explosion-proof dust extraction with an integrated inert fluid neutralisation system, safely treating combustible metal dust before it enters the collection container.In addition to its external ATEX Zone 22 certification, the vacuum is also internally certified for Zone 20, providing an additional level of protection within the vacuum during the collection of combustible dust.
For manufacturers processing aluminium, titanium, magnesium, and other reactive metals within classified dust explosion risk zones, the DG50 EXP INERT offers one of the most comprehensive safety solutions available. Combining ATEX Zone 22 certification with independently certified inert technology, it provides enhanced protection where conventional industrial vacuum cleaners may not adequately address the hazards associated with reactive metal dust. Its internal Zone 20 certification provides an extra level of protection by recognising that combustible dust may be continuously present inside the vacuum during normal operation.
________________________________________
ATEX Industrial Vacuum for Reactive Metal Dust Applications
The DG50 EXP INERT is purpose-built for industries handling combustible and pyrophoric metal dusts, including:
- Foundries
- Aerospace manufacturing
- Aluminium processing facilities
- Titanium machining operations
- Magnesium processing plants
- Metal fabrication in classified ATEX environments
- Industrial manufacturing facilities handling reactive metal dust
In these environments, reactive metal dust presents unique ignition hazards that require more than standard dust extraction. The DG50 EXP INERT actively neutralises collected dust during the extraction process, helping minimise the risk of self-heating, combustion, and ignition while maintaining compliance within classified ATEX Zone 22 areas.
________________________________________
What Makes This ATEX Certified Industrial Vacuum Different?
Integrated Inert System for Reactive Dust – Neutralises Self-Igniting Metal Dust During Collection
The defining feature of the DG50 EXP INERT is its advanced inert fluid neutralisation system.
Designed specifically for highly reactive and combustible metal dusts, the system safely treats collected material before it accumulates within the collection container.
Suitable for collecting:
- Aluminium dust
- Titanium dust
- Magnesium dust
- Other reactive and combustible metal powders
Unlike conventional ATEX industrial vacuum cleaners, the DG50 EXP INERT neutralises reactive dust during collection, significantly reducing the risk of ignition within the vacuum.
Key benefits include:
- Neutralisation efficiency exceeding 95%
- Independently certified by an accredited third-party body
- Designed specifically for reactive and self-igniting metal dust
- Certified in accordance with UNI EN 17348:2022
- Provides additional protection beyond standard ATEX compliance
For facilities processing reactive metals, inert technology provides an essential layer of safety that conventional industrial vacuum cleaners cannot offer.
________________________________________
ATEX Zone 22 Certification for Hazardous Dust Environments
The DG50 EXP INERT is fully ATEX Zone 22 certified, making it suitable for the safe collection of combustible and reactive metal dust in classified dust explosion risk areas. For additional safety, the vacuum is also internally certified for Zone 20, ensuring protection within the collection chamber where combustible dust is continuously present during operation.
What sets this industrial vacuum apart is the combination of its ATEX certification with an independently certified inert neutralisation system. Certified by an accredited third-party body, the inert system achieves a neutralisation efficiency of over 95%, significantly reducing the risk of ignition when collecting self-igniting metal dust.
Powered by a 4.6 kW ATEX-certified three-phase side channel blower, the DG50 EXP INERT delivers powerful, continuous-duty suction while providing the highest levels of protection for hazardous dust applications.
The combination of ATEX Zone 22 certification and third-party certified inert technology makes the DG50 EXP INERT one of the most complete certified solutions available for the safe management of reactive metal dust in classified industrial environments.
________________________________________
Advanced Filtration System for Hazardous Dust
The DG50 EXP INERT incorporates a high-performance filtration system designed to safely contain hazardous dust while maintaining consistent airflow.
Filtration features include:
- Antistatic polyester M-Class primary filter
- Integrated manual filter cleaning system
- HEPA filter fitted as standard
- High-efficiency filtration for hazardous dust containment
The HEPA filter ensures exceptionally clean exhaust air by capturing fine particulate matter before air is returned to the workplace.
For facilities handling combustible or reactive dust, efficient filtration is a critical part of maintaining both workplace safety and regulatory compliance.
________________________________________
Robust Mobile Design for Industrial Applications
Designed for demanding manufacturing environments, the DG50 EXP INERT combines industrial durability with compact mobility.
Construction features include:
- Compact mobile footprint
- Heavy-duty painted steel construction
- Integrated ABS accessory holder
- Continuous-duty operation
- Low-maintenance design
- Safety limiting valve included as standard
Its wheeled design allows operators to easily transport the vacuum between workstations while maintaining safe operation within classified production areas.
________________________________________
Why Choose the Delfin DG50 EXP INERT?
When comparing ATEX industrial vacuum cleaners, many provide explosion protection but are not specifically designed to safely manage reactive metal dust.
The Delfin DG50 EXP INERT stands out because it offers:
- ATEX Zone 22 certified with additional internal Zone 20 certification for enhanced protection
- Integrated inert neutralisation system with over 95% certified efficiency
- Independently tested and certified performance
- Suitable for aluminium, titanium, magnesium, and other reactive metal dusts
- Powerful 4.6 kW ATEX-certified side channel blower
- M-Class antistatic filtration with HEPA filtration as standard
- Compact mobile design for industrial environments
- Durable painted steel construction with ABS accessory holder
- Continuous-duty, low-maintenance operation
- Full compliance with ATEX 2014/34/EU, UNI EN 17348:2022 and EN IEC 62784:2018
The combination of ATEX certification and certified inert technology makes the DG50 EXP INERT one of the only certified solutions available for the safe management of reactive metal dust in ATEX Zone 22 classified areas.
________________________________________
Frequently Asked Questions (FAQ’s)
What is an inert system?
An inert system uses a specialised neutralising fluid to safely treat reactive metal dust during collection. This helps minimise the risk of self-heating, combustion, and ignition within the collection container.
What types of dust can the DG50 EXP INERT collect?
The vacuum is specifically designed for reactive and combustible metal dusts including aluminium, titanium, magnesium, and other self-igniting metal powders, as well as dry dust and solid materials.
What does ATEX Zone 22 mean?
Zone 22 refers to areas where explosive dust atmospheres are not likely to occur during normal operation but, if they do occur, will only exist for short periods. Equipment used within these areas must comply with ATEX certification requirements. The DG50 EXP INERT also benefits from internal Zone 20 certification, providing an additional level of protection inside the vacuum where combustible dust is present throughout the collection process.
Has the inert system been independently tested?
Yes. The inert neutralisation system has been independently certified by an accredited third-party organisation and achieves neutralisation efficiency greater than 95% in accordance with UNI EN 17348:2022.
Which industries commonly use this vacuum?
Typical applications include aerospace manufacturing, aluminium processing, titanium machining, magnesium processing, light alloy foundries, and industrial facilities handling reactive metal dust within classified ATEX environments.
Can the DG50 EXP INERT collect liquids?
No. The DG50 EXP INERT is designed specifically for the collection of dry dust and solid materials. It is not intended for liquid extraction.
________________________________________
Summary
The Delfin DG50 EXP INERT is a specialist industrial vacuum cleaner developed for the safe collection and neutralisation of reactive metal dust within ATEX Zone 22 hazardous environments. Combining a powerful 4.6 kW ATEX-certified side channel blower with an independently tested inert neutralisation system, it provides one of the most advanced safety solutions available for facilities processing aluminium, titanium, magnesium, and other combustible metal powders. Alongside its external ATEX Zone 22 certification, the vacuum is also internally certified for Zone 20, providing an additional level of protection during the collection of combustible dust.
With certified neutralisation performance, high-efficiency M-Class and HEPA filtration, continuous-duty operation, and robust industrial construction, the DG50 EXP INERT delivers outstanding performance while helping manufacturers safely manage reactive dust in compliance with ATEX regulations.
To view more of our Inert Vacuums: INERT ATEX Industrial Vacuums













